当前位置: 首页 > 文章 > 高效液相色谱法测定鱼、虾和鸡肉中的呋喃唑酮残留 湖北农业科学 2013,52 (16) 3974-3976
Position: Home > Articles > Determination of Furazolidone Residue in Fish, Shrimp and Chicken by HPLC Hubei Agricultural Sciences 2013,52 (16) 3974-3976

高效液相色谱法测定鱼、虾和鸡肉中的呋喃唑酮残留

作  者:
余晓;苏子豪;翟海云;卢绮雯;潘育方
单  位:
广东药学院
关键词:
呋喃唑酮;药物残留;高效液相色谱法
摘  要:
建立高效液相色谱(HPLC)法测定鱼、虾和鸡肉中呋喃唑酮药物残留量的方法。色谱条件为Kromasil C18(250 mm×4.6 mm,5μm)柱,流动相乙腈-0.1%磷酸水溶液(30∶70,V/V),流速1.0 mL/min,检测波长365 nm,柱温25℃。结果表明,呋喃唑酮标准溶液在0.2~5.0 ng范围内与峰面积呈良好的线性关系(r=0.999 1),检出限为0.2μg/kg(S/N=3)。样品平均加标回收率为97.7%~102.9%,RSD为1.1%~1.5%(n=6)。该方法简单、快速、灵敏度高、重复性好,适用于鱼、虾和鸡肉中呋喃唑酮的残留分析。
译  名:
Determination of Furazolidone Residue in Fish, Shrimp and Chicken by HPLC
作  者:
YU Xiao;SU Zi-hao;ZHAI Hai-yun;LU Qi-wen;PAN Yu-fang;Guangdong College of Pharmacy;
关键词:
furazolidone;;drug residue;;HPLC
摘  要:
The HPLC method for detecting furazolidone residue in fish, shrimp and chicken samples was established. The sample was seperated in the Kromasil C18column(250 mm×4.6 mm,5 μm) with acetonitrile-0.1% phosphoric acid solution(30∶70, V / V) at 25 ℃; the flow rate was 1.0 mL / min. The detecting wavelength was set at 365 nm. The results showed that the linear range of furazolidone was 0.2~5.0 ng(r=0.999 1), the LOD was 0.2 μg / kg(S/N=3). The average recovery was 97.7%~102.9% with the RSD of 1.1~1.5%(n=6). In conclusion, this simple, rapid, sensitive and reproducible method was suitable for analyzing the furazolidone residue in chicken, fish and shrimp.