当前位置: 首页 > 文章 > 电磁流量计测量误差分析 河南农业大学学报 2000,34 (3) 266-268
Position: Home > Articles > Measuring error analysis of electromagnetic flowmeter Journal of Henan Agricultural University 2000,34 (3) 266-268

电磁流量计测量误差分析

作  者:
李克奇;袁维宝;何予鹏
单  位:
华北水利水电学院;河南农业大学;中州铝厂
关键词:
电磁流量计;励磁;测量;误差
摘  要:
分析了测量流体时附着物影响导致零点变动、电导率的变化而产生静电感应躁声、非轴对称流动导致流速分布不对称引起的电磁流量计测量误差 .提出了生产过程中消除测量误差的方法 ,选择合适的内衬、增大流速、消除静电感应躁声、在电磁流量计前面有足够长的直管
译  名:
Measuring error analysis of electromagnetic flowmeter
作  者:
LI Ke qi 1,YUAN Wei bao 2,HE Yu peng 3 (1 Zhongzhou Aluminium Plant,Jiaozuo 454174,China;2.Huabei Hydroeletric Power Institute,Zhengzhou 450008,China;3 Henan Agricultural University,Zhengzhou 450002,China)
关键词:
electromagnetic flowmeter;magnetization;measuring;error
摘  要:
An analysis is presented of the measuring error of electromagnetic flowmeter caused by zeropoint moves by deposition in measuring flow static induction noise caused by electric conductance change and unsymmetrie velocity distribution caused by axis of unsymmetric flow.And the ways to eliminate measuring error selecting fitting lining,increasing flow rate removing static induction noise and fixing long enough straight duct before electromagnetic flowmeter.