当前位置: 首页 > 文章 > 胃舒平片剂中铝含量测定方法研究 安徽农业科学 2007,35 (24) 14+16
Position: Home > Articles > Study on the Method of Determining Aluminum Content in Compound Aluminum Hyclroxide Tablets Journal of Anhui Agricultural Sciences 2007,35 (24) 14+16

胃舒平片剂中铝含量测定方法研究

作  者:
加建斌
单  位:
榆林学院生命科学学院
关键词:
胃舒平;铝含量;酸碱滴定法
摘  要:
研究了胃舒平片剂中铝含量的测定方法。样品消解后,先在pH值为7~8时,用稀NaOH溶液将Al3+沉淀为Al(OH)3,再加入KCl,反应中生成的游离KOH溶液,以酚酞为指示剂,用HCl标准溶液滴定至终点。加标回收率(R)在96.8%~100.1%,测定结果的相对标准偏差(RSD)<1.0%。结果表明,改进后的方法,操作方便、测定快捷,其准确度和精密度与标准法一致。
译  名:
Study on the Method of Determining Aluminum Content in Compound Aluminum Hyclroxide Tablets
作  者:
JIA Jian-bin(School of Life Science,Yulin College,Yulin,Shaanxi 719000)
关键词:
Compound aluminum hyclroxide;Aluminum content;Acid-base titration
摘  要:
The study on the method of determining aluminum content in compound aluminum hyclroxide tablets was conducted.The sample was digesting,the Al3+ was deposited as Al(OH)3 with thin solution of NaOH,while that remains pH 7~8.Then,KF was added and dissociated KOH was released.With phenolphthalein as the indicator and HCl as the standard solution,dissociated KOH was titrated to end point.The recovery of standard addition was between 96.8% and 100.1%,and the relative standard deviation of determination result was <1.0 %.The results showed that the improved method was a facility-operating way with the fast determination.The accuracy and precision of this method accorded with those of national standard method.