当前位置: 首页 > 文章 > 基于Nafion/天青A/纳米金层层自组装固定酶的过氧化氢生物传感器 安徽农业科学 2008,36 (18) 193-195+267
Position: Home > Articles > Hydrogen Peroxide Biosensor Based on the Layer-by-layer Self-assembly Immobilized Enzyme of Nafion,Azure A,Nano-gold Journal of Anhui Agricultural Sciences 2008,36 (18) 193-195+267

基于Nafion/天青A/纳米金层层自组装固定酶的过氧化氢生物传感器

作  者:
李华刚;袁若;柴雅琴;苗向敏;卓颖;洪成林
单  位:
发光与实时分析教育部重点实验室(西南大学)西南大学化学化工学院
关键词:
Nafion;天青A;纳米金;辣根过氧化物酶;生物传感器
摘  要:
[目的]明确基于Nafion、天青A、纳米金层层自组装固定酶制备过氧化氢生物传感器的可行性。[方法]先利用静电吸附和自组装技术将Nafion、天青A、纳米金修饰到金电极表面,然后利用纳米金吸附辣根过氧化物酶(HRP),制备过氧化氢生物传感器。采用循环伏安法和计时电流法考察该传感器的性能。[结果]在测试溶液pH值5.5、工作电位-0.3~-0.2 V、扫速100 mV/s、检测温度25℃条件下,该传感器具有良好的生物催化活性,还原峰电流与H2O2浓度在2.0×10-6~1.6×10-3mol/L范围内呈良好的线性关系,检出限为7.62×10-7mol/L。该传感器稳定性好,抗干扰力强,制备方法简单,成本低廉,对H2O2有快速灵敏的响应。[结论]该研究制备的过氧化氢生物传感器灵敏度较高,检测范围宽,检出限较低。
译  名:
Hydrogen Peroxide Biosensor Based on the Layer-by-layer Self-assembly Immobilized Enzyme of Nafion,Azure A,Nano-gold
作  者:
LI Hua-gang et al(Key Laboratory on Luminescence and Red-Time Analysis(Southwest University),Ministry of Education,College of Chemistry and Chemical Engineering,Southwest University,Chongqing 400715)
关键词:
Nafion;Azure A;Nano-gold;Horseradish peroxidase;Biosensor
摘  要:
[Objective] The research aimed to confirm the feasibility of preparing hydrogen peroxide biosensor based on layer-by-layer self-assembly immobilized enzyme of Nafion,azure A,nano-gold.[Method] Nafion,azure A and nano-gold were decorated on the golden electrode surface by using electrostatic adsorption and self-assembly technology.Horseradish peroxidase was adsorbed by using nano-gold to prepare hydrogen peroxide biosensor.The performances of this sensor were observed by using cyclic voltammetry method and chronoamperometry.[Result] Under the conditions that pH value of test solution was 5.5,working potential was-0.3~-0.2 V,sweep speed was 100 mV/s and the detection temperature was 25 ℃,this sensor had good biology catalytic activity.The reduction peak current showed a good linear correlation with H2O2 concn.in the range of 2.0×10-6~1.6×10-3 mol/L and the detection limit was 7.62×10-7 mol/L.This sensor had good stability,strong anti-disturbance capability,simple preparing method,cheap cost and rapid and sensitive response to H2O2.[Conclusion] The prepared hydrogen peroxide biosensor had higher sensitivity,broad detection range and lower detection limit.

相似文章

计量
文章访问数: 11
HTML全文浏览量: 0
PDF下载量: 0

所属期刊

推荐期刊