当前位置: 首页 > 文章 > 微波消解-氢化物发生原子荧光法测定保健食品中的硒含量 湖北农业科学 2008,47 (2) 223-225
Position: Home > Articles > Determination of Selenium in Healthy Food by Hydride Generation-Atomic Fluorescence Spectrometry Method Hubei Agricultural Sciences 2008,47 (2) 223-225

微波消解-氢化物发生原子荧光法测定保健食品中的硒含量

作  者:
刘波;孟辉
单  位:
辽东学院材料科学与化学工程学院化工系
关键词:
硒;灵芝孢子粉;超微康硒原粉;富硒大米;氢化物发生-原子荧光法
摘  要:
采用微波消解-氢化物发生原子荧光法(HG-AFS)测定灵芝孢子粉、超微康硒原粉及富硒大米中的硒含量,结果该法检出限为3 ng,线性范围为0.01~0.20μg,平均回收率为87.5%~101.2%(n=5)。该法简单、可靠、重现性好,灵敏度高。
译  名:
Determination of Selenium in Healthy Food by Hydride Generation-Atomic Fluorescence Spectrometry Method
作  者:
LIU Bo,MENG Hui(Department of Chemical Engineering Institute of Equipment and Material Liao Dong Institute,Dandong 118003,Liaoning,China)
关键词:
selenium;Ganoderma lucidum spores;Chaoweikangxiyuanfen selenium-enriched rice;HG-AFS
摘  要:
This paper created a method to determinate selenium.Determinate selenium in Ganoderma lucidum spores Chaoweikang xiyuanfen and Selenium-enriched rice by microwave digestion HG-AFS method.The detection limit(DL) of the method was 3.0 ng,the linear range was 0.01 μg~0.2 μg and the average recovery was 87.5%~101.2%(n=5).The method was accurate,simple and well reproducible.