当前位置: 首页 > 文章 > 国标分光光度法测定面制食品中铝的改进研究 西南农业学报 2010,23 (5) 1766-1769
Position: Home > Articles > Spectrophotometric Determination of Aluminum in Flour Food Using Dry Ashing-Dissolved Samples through Nitric Acid Solution Southwest China Journal of Agricultural Sciences 2010,23 (5) 1766-1769

国标分光光度法测定面制食品中铝的改进研究

作  者:
谢永红;杨定清;罗晓梅;周娅
单  位:
四川省农科院分析测试中心
关键词:
干灰化;硝酸;面制食品;铝;测定
摘  要:
采用干灰化法-硝酸溶液溶解样品,分光光度法测定面制食品中铝。结果表明,溶液酸度控制在0.2%为最佳,最佳测定时间以20 min为宜,该法精密度RSD%在7.0~8.5之间,添加回收率在92.5%~99.2%之间,与国标比色法比较,结果无显著差异,其中精密度还优于国标比色法。该法完全可以作为目前国标比色方法的补充,适于批量样品测定,前处理液可用于其它金属元素联测,对实现低碳绿色分析具有现实意义。
译  名:
Spectrophotometric Determination of Aluminum in Flour Food Using Dry Ashing-Dissolved Samples through Nitric Acid Solution
作  者:
XIE Yong-hong,YANG Ding-qing,LUO Xiao-mei,ZHOU Ya(Testing Center of Sichuan Academy of Agricultural Sciences,Sichuan Chengdu 610066,China)
关键词:
Ashing;Nitric acid;Flour food;Aluminum;Determination
摘  要:
Samples were dissolved by nitric acid after ashing,and aluminum was tested by spectrophotometry,the results showed that the best acidity of nitric acid was 0.2 %,the best measured time was 20 min,the precision RSD % was between 7.0 %-8.5 %,and the recoveries were between 92.5 %-99.2 %.Compared with the GB code color method,the result had no remarkable difference,in which accuracy also surpassed the GB code color method.The method could be as a supplementary method for current national standard,and suited for the determination of bulk samples,the pre-treatment solution could be used as other metallic elements associated measurements.