Position: Home > Articles > Heat Conservation Effects of the Underground Heat Storage System in Double-film Covering Greenhouse
Transactions of the Chinese Society for Agricultural Machinery
2006,37
(1)
103-106
双层覆盖温室地下蓄热系统保温效果试验
作 者:
王永维;梁喜凤;苗香雯
单 位:
中国计量学院机电工程学院;浙江大学生物系统工程与食品科学学院
关键词:
双层覆盖温室;地下蓄热系统;保温效果;试验
摘 要:
针对温室加温能耗大的突出问题,设计了双层覆盖温室地下蓄热系统。测试了冬季夜间保温时温室内外温度、湿度,计算了达到同样环境温度时燃煤热水锅炉加温所需能耗及燃料成本。结果表明,在冬季白昼为晴天、多云、阴天时,双层覆盖温室地下蓄热系统蓄热后,夜间保温时温室内温度分别高于外界温度5.1~9.8℃、4.8~6.9℃、4.2~6.4℃,室内外平均温差分别为6.9℃、5.4℃、5.3℃,其能耗费用低于燃煤热水锅炉加温费用,系统具有良好的保温性能,节能效果明显。
译 名:
Heat Conservation Effects of the Underground Heat Storage System in Double-film Covering Greenhouse
作 者:
Wang Yongwei1 Liang Xifeng2 Miao Xiangwen1 (1.Zhejiang University 2.China Jiliang University)
关键词:
Double-film covering greenhouse, Underground heat storage system, Heat conservation effect, Experiments
摘 要:
In order to reduce energy consumption in greenhouse, the underground heat storage system with double-film covering was designed based on the plant physiology. The temperature and humidity inside and outside greenhouse were measured during heat conservation at night. At the same time, the energy consumption and the fuel cost of the coal-fired hot water boiler were calculated when the temperature in greenhouse reach the temperature measured above. It was indicated that the inside temperature were 5.1~9.8℃、4.8~6.9℃、4.2~6.4℃ higher than the outside temperature respectively and the average temperature difference between inside and outside greenhouse were 6.9℃、5.4℃、5.3℃ during heat conservation at night after heat storage in the clear day, cloudy sky and over cloudy sky in winter. Moreover, the energy consumption cost was less than the heating cost of the coal-fired hot water boiler. So the heat conservation and energy saving of the system is significant.
相似文章
-
空气流速对温室地下蓄热系统湿热传递影响试验 [梁喜凤, 王永维, 程绍明, 王俊, 苗香雯] 农业机械学报 2010,41 (8) 194-199