当前位置: 首页 > 文章 > 单向偏心受压基础直接计算新方法 河北农业大学学报 1997 (2) 99-102
Position: Home > Articles > A New Method to Direct Calculate the Size of One-dimensional Eccentrically Loaded Footing Journal of Agricultural University of Hebei 1997 (2) 99-102

单向偏心受压基础直接计算新方法

作  者:
王士杰;李立华;马凤奎;宇云飞
单  位:
河北农大城乡建设学院
关键词:
柱下独立基础;单向偏心受压;长宽比;偏心距;基底尺寸;地基承载力
摘  要:
本文给出了柱下独立基础单向偏心受压时基底尺寸的直接计算公式。可较快地求得充分利用地基承载能力、经济合理的基础底面积。
译  名:
A New Method to Direct Calculate the Size of One-dimensional Eccentrically Loaded Footing
作  者:
Wang Shijie; Li Lihua ;Ma Fengkui; Yu yunfei (School of Urban and Rural Construction,Hebei Agri. Univ.,Baoding 071001).
关键词:
Individual footing under columns; One-dimensional eccentrically load; Ratio of length to width; Eccentricity; Size of footing; Bearing capacity
摘  要:
A formula is shown in the paper to calculate directly the size of individual footing under columns for one - dimensional eccentric compression. The formula is able to work out rapidly the economical and reasonable footing size which maximize the utility of its bearing capacity.

相似文章

计量
文章访问数: 10
HTML全文浏览量: 0
PDF下载量: 0

所属期刊

推荐期刊