当前位置: 首页 > 文章 > 超声波解冻对鸡胸肉品质的影响 食品科学 2018 (5) 135-140
Position: Home > Articles > Effect of Ultrasonic Thawing Method on Quality Characteristics of Chicken Breast Meat FOOD SCIENCE 2018 (5) 135-140

超声波解冻对鸡胸肉品质的影响

作  者:
张昕;宋蕾;高天;张林;江芸;李蛟龙;高峰;周光宏
单  位:
南京师范大学金陵女子学院;南京农业大学动物科技学院江苏省动物源食品生产与安全保障重点实验室江苏省肉类生产与加工质量安全控制协同创新中心
关键词:
超声波解冻;静水解冻;鸡胸肉;肉品质
摘  要:
本实验旨在研究超声波解冻对鸡胸肉品质的影响。以15℃静水解冻组为对照组,在同样水温条件下,以4种不同功率(120、180、240、300 W)超声波解冻组为实验组,分析不同功率超声波解冻对鸡胸肉品质的影响。结果表明:与对照组相比,超声波解冻后鸡胸肉红度(a*值)显著升高,解冻时间显著缩短,细菌总数显著降低(P<0.05),但其解冻汁液流失率、T_(23)(表征自由水)峰面积比显著升高(P<0.05),pH值、亮度(L*值)、总蛋白溶解度和肌原纤维蛋白溶解度显著降低(P<0.05);与240 W和300 W超声波处理组相比,120 W和180 W超声波解冻后鸡胸肉剪切力、总蛋白溶解度和肌原纤维蛋白溶解度显著升高(P<0.05),T_(23)峰面积比显著降低(P<0.05),而180 W超声波处理组细菌总数显著低于120 W处理组(P<0.05)。综合分析,与静水解冻相比,超声波解冻工艺可有效提高鸡胸肉解冻速率并显著改善新鲜度,但解冻后鸡胸肉蛋白质变性导致保水性较差,解冻汁液流失率高且肉色偏暗,对解冻后鸡胸肉品质有一定的负面影响,其中180 W超声波解冻对鸡胸肉品质负面影响最小。
译  名:
Effect of Ultrasonic Thawing Method on Quality Characteristics of Chicken Breast Meat
作  者:
ZHANG Xin;SONG Lei;GAO Tian;ZHANG Lin;JIANG Yun;LI Jiaolong;GAO Feng;ZHOU Guanghong;Jiangsu Collaborative Innovation Center of Meat Production and Processing, Quality and Safety Control, Key Laboratory of Animal Origin Food Production and Safety Guarantee of Jiangsu Province, College of Animal Science and Technology, Nanjing Agricultural University;Ginling College, Nanjing Normal University;
关键词:
ultrasonic thawing;;water immersing thawing;;chicken breast;;meat quality
摘  要:
The effect of ultrasonic thawing method on quality characteristics of chicken breast meat was investigated. Water thawing(15 ℃) was taken as the control group while four experimental groups were set up: thawing at different ultrasonic powers(15 ℃; 120, 180, 240 and 300 W). The differences in quality parameters of the thawed samples were analyzed. The results showed that compared with the control group, the a* value of thawed chicken breast in the experimental groups increased significantly, and thawing time and total bacterial count decreased(P < 0.05). However, the thawing loss and T_(23) peak area ratio of all ultrasonic thawing treatments were significantly higher(P < 0.05), and pH, L* value, total protein solubility, and myofibril protein solubility were significantly lower than those in the control group(P < 0.05). The shear force, total protein solubility and myofibrillar protein solubility in the 120 and 180 W groups were significantly higher compared with 240 and 300 W ultrasonic treatment(P < 0.05), and T_(23) peak area ratio was significantly lower(P < 0.05). Furthermore, significantly lower total bacterial count was resulted from ultrasonic thawing at 180 W than at 120 W(P < 0.05). Overall, ultrasonic thawing treatment could effectively improve the thawing rate along with a significant improvement in the freshness of chicken breast meat; however, it had a detrimental effect on the water-holding capacity and color and exacerbated the degree of protein denaturation and the least negative effect was observed at 180 W.

相似文章

计量
文章访问数: 4
HTML全文浏览量: 0
PDF下载量: 0

所属期刊

推荐期刊