当前位置: 首页 > 文章 > 33.5%喹啉铜悬浮剂的气相色谱分析研究 现代农药 2011,10 (5) 38-39+43
Position: Home > Articles > Analysis of Oxine-copper 33.5% SC by GC Modern Agrochemicals 2011,10 (5) 38-39+43

33.5%喹啉铜悬浮剂的气相色谱分析研究

作  者:
郭利丰;肖鸣;黄雅俊
单  位:
浙江省农药检定管理所
关键词:
喹啉铜;气相色谱;分析
摘  要:
叙述了采用气相色谱法以邻苯二甲酸二甲酯为内标,用Elite-17毛细管柱、FID检测器对喹啉铜的气相色谱分析方法。采用该方法分析喹啉铜的线性相关系数为0.9998,变异系数为0.49%,平均回收率99.3%。该方法操作简便,适用于产品的常规分析和质量控制。
译  名:
Analysis of Oxine-copper 33.5% SC by GC
作  者:
GUO Li-feng,XIAO Ming,HUANG Ya-jun(Institute for the Control of Agrochemicals of Zhejiang Province,Hangzhou 310020,China)
关键词:
oxine-copper;GC;analysis
摘  要:
A method for the determination of oxine-copper 33.5% SC was developed by GC with Elite-17 capillary column,FID detector and dimethyl phthalate as internal standard.The results showed that the linear correlation coefficient was 0.9998,the variation coefficient was 0.49%,and the average recovery was 99.3%.The method is simple and suitable for routine analysis and quality control of oxine-copper 33.5% SC.

相似文章

计量
文章访问数: 10
HTML全文浏览量: 0
PDF下载量: 0

所属期刊

推荐期刊