Position: Home > Articles > Double Membrane Amplification of the Amperometric Immunosensor for Sensing Carcinoembryonic Antigen
Journal of Shihezi University(Natural Science)
2012,30
(4)
118-122
双层膜放大的电流型癌胚抗原免疫传感器的研究
作 者:
王丽;孙涛;谭超
单 位:
宜宾学院化学与化工学院
关键词:
纳米铂;普鲁士蓝;癌胚抗原;免疫传感器
摘 要:
以金电极为电极材料,纳米铂/普鲁士蓝复合物膜为固载基底,癌胚抗体(anti-CEA)为模板免疫蛋白质分子,研制成一种高灵敏电流型癌胚抗原免疫传感器。该传感器以辣根过氧化氢酶(HRP)代替牛血清白蛋白封闭非特异性结合位点,放大了电流信号,提高了电极的灵敏度,并采用循环伏安技术对电极的制备过程进行了研究。在优化的实验条件下,该传感器响应的峰电流值与癌胚抗原浓度在1.0~80.0ng/mL的范围内保持良好的线性关系,检测限为0.4ng/mL。
译 名:
Double Membrane Amplification of the Amperometric Immunosensor for Sensing Carcinoembryonic Antigen
作 者:
WANG Li,SUN Tao,TAN Chao(College of Chemistry and Chemical Engineering,Yibin University,Yibin 644007,China)
关键词:
platinum nanoparticle;prussian blue;carcinoembryonic antigen;immunosensor
摘 要:
A new amperometric immunosensor for the determination of carcinoembryonic antigen(CEA) was developed by means of immobilizing carcinoembryonic antibody onto the nano-Pt/ Prussian-blue-modified composite film.The research substituted Horseradish peroxidase(HRP) for bovine serum albumin(BSA) to block nonspecific binding sites and amplify the current signal of the antigen-antibody reaction.Cyclic voltammetry(CV) was employed to characterize the assembly process.Under the optimized conditions,the response current of the proposed immunosensor has a good linear relationship with CEA in the concentration ranges from 1.0 to 80.0 ng/mL with a detection limit of 0.2 ng/mL.
相似文章
-
基于季铵化聚乙烯吡啶和纳米铂固定血红蛋白的过氧化氢生物传感器的研究 [滕瑛丽, 刘昌华, 郭晓利] 西南大学学报(自然科学版) 2010,32 (3) 39-44