当前位置: 首页 > 文章 > 离子液体分散液—液微萃取—高效液相色谱法测定碳酸饮料中合成着色剂 黑龙江八一农垦大学学报 2017 (3) 65-69
Position: Home > Articles > Simultaneous Determination of Synthetic Colorants by Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography in Carbonated Drink Journal of Heilongjiang Bayi Agricultural University 2017 (3) 65-69

离子液体分散液—液微萃取—高效液相色谱法测定碳酸饮料中合成着色剂

作  者:
孙鹏;竺鉴博;高玉玲
单  位:
大庆市萨尔图区市场监督管理局食品药品服务中心;黑龙江八一农垦大学
关键词:
离子液体;高效液相色谱;分散液液微萃取;合成着色剂
摘  要:
建立了一种离子液体分散液液微萃取样品前处理技术,结合高效液相色谱法测定液态奶中2种着色剂(胭脂红、日落黄)。考察了萃取剂种类、萃取剂体积、分散剂种类、p H、盐浓度等因素对萃取效率的影响。确定了最佳萃取条件:以160μL 1-辛基-3-甲基咪唑六氟磷酸盐([OMIM]PF6)为萃取剂,1 000μL乙腈为分散剂,Na Cl质量分数为6%,p H为4.5。结果表明:2种合成着色剂在1~250μg·L~(-1)范围内呈良好的线性关系,线性相关系数为0.998 8~0.999 2;检出限分别为1.27μg·L~(-1)和0.43μg·L~(-1),加标回收率在88.7%~98.5%,RSD在1.3%~5.4%。该方法简单、高效、安全,能够满足碳酸饮料中合成着色剂的检测要求。
译  名:
Simultaneous Determination of Synthetic Colorants by Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography in Carbonated Drink
作  者:
Sun Peng;Zhu Jianbo;Gao Yuling;Heilongjiang Bayi Agricultural University;Food and Drug Service Center of Market Supervision Administration,Sartu District;
关键词:
ionic liquid;;performance 1iquid chromatography;;dispersive 1iquid-liquid microextraction;;synthetic colorants
摘  要:
A novel method for the determination of two synthetic colorants ponceau 4R and sunset yellow from the carbonated drink was developed using ionic liquid dispersive 1iquid-liquid microextraction coupled with high performance liquid chromatography.The influence of extraction parameters including types of extraction solvent,volume of extraction solvent,types of dispersant solven,p H,sodium chloride mass fraction were investigated.Using 160 μL 1-octyl-3-methylimidazolium hexafluorophosphate([OMIM]PF6)as extraction drop,1 000 μL acetonitrile as dispersant solvent,sodium chloride mass fraction 6%,p H was adjusted 4.5 Under the optimal condition,good linear relationship was obtained in the two synthetic colorants concentrations of 1-250 μg·L-1 with the correlation coefficients of 0.998 8-0.999 2;the detection limits were 0.43-1.27 μg·L-1.The proposed method was applied to the determination of two synthetic colorants in carbonated drink,the recoveries were from 88.7% to 98.5%,with the corresponding relative standard deviations were from 1.3% to 5.4%. The method was simple,fast and precise to satisfy,which could meet the requirements for the determination of synthetic colorants in carbonated drink.

相似文章

计量
文章访问数: 9
HTML全文浏览量: 0
PDF下载量: 0

所属期刊

推荐期刊